No customs fees! Products from within the EU
APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets
MPN: APDU11550ME
Quick Code: B52714997
(APC NetShelter Rack PDU Advanced - Power distribution unit [rack-mountable] - switched, metered, 415 V - AC 415 V - 69000 VA - 3-phase - Ethernet 10/100/1000 - input: IEC 60309 100A - output connectors: 36 [18 x IEC 60320 C13/C15, 18 x IEC 60320 C13/C15/C19/C21] - 0U - 3 m cord - black)
Note: Image accuracy is not guaranteed. Please do not rely solely on the image for your purchase.
$4653.85
$5584.62 inc. VAT
All products on this website are available duty-free in the EU
Overseas Customers with EU-VAT number do not pay VAT. - Verify it here
Overseas Customers with EU-VAT number do not pay VAT. - Verify it here
Quick Code:
B52714997
MPN:
APDU11550ME
Manufacturer:
APC
EAN Code:
0731304775621
💰 Get $33.51 Cash Back if paying by Debit Card or Bank Transfer!
NOTE: The information below is provided for your convenience only and we cannot guarantee its accuracy. If necessary, please verify with us before purchasing.
APC NetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 OutletsNetShelter Rack PDU Advanced Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets
APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks in ZeroU form. PDU level power metering provides power visibility and notification of potential overload. 50 percent of outlets on model are designed as 4 in 1 combination outlets which can be used as either C13, C19, C15, or C21 to provide unparalleled deployment flexibility. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today s high density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs have the following certifications: UL, CE, CSA, UKCA, Nemiko, PSE, KC, China RoHS, RCM, and CMIM. This model’s input power cord is 5125P6W 100A and features 18 count C13/C15 and 18 count C13/C15/C19/C21 outlets. A 9.8 foot (3 meter) input cord makes it easier for the PDU to reach the power supply.