APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet
MPN: APDU11450SM
Quick Code: B50948757
(APC NetShelter Rack PDU Advanced - Gen 2 - power distribution unit [rack-mountable] - switched, metered, 43.5kW, 400V, 63A, or, 415V, 60A, 560P6 - AC 400/415 V - 34.6 kW - 34600 VA - 3-phase - Ethernet 10/100/1000, USB - input: IEC 60309 3P+N+PE - output connectors: 42 [21 x IEC 60320 C13/C15/C19/C21, 21 x IEC 60320 C13/C15] - 0U - 3 m cord - black - TAA Compliant)
Note: Image accuracy is not guaranteed. Please do not rely solely on the image for your purchase.
$5375.36
$6450.43 inc. VAT
All products on this website are available duty-free in the EU
Overseas Customers with EU-VAT number do not pay VAT. - Verify it here
Overseas Customers with EU-VAT number do not pay VAT. - Verify it here
Quick Code:
B50948757
MPN:
APDU11450SM
Manufacturer:
APC
EAN Code:
0731304752790
💰 Get $38.70 Cash Back if paying by Debit Card or Bank Transfer!
NOTE: The information below is provided for your convenience only and we cannot guarantee its accuracy. If necessary, please verify with us before purchasing.
APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 OutletNetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet,3Phase, 43.5kW 400V 63A or 34.6kW 415V 60A, 560P6, 42 Outlet
APC NetShelter Rack PDU Advanced (11K Series) provides reliable power distribution to IT equipment within server and/or networking racks. Switched outlets allow for turning outlets on or off remotely. Outlet and PDU level power metering provide power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparalleled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 in. (5.6 cm) wide form factor allows for more equipment in the rack. Outlets on the PDUs are color coded and labeled by breaker. Live Swap the NMC3 to minimize downtime in the unlikely event of an NMC power event. The rack PDU integrates with EcoStruxure IT through an NMC3 and can be accessed and configured via web, SNMP, and command line interface (CLI). A 10-foot (3-meter) input cord makes it easier for the PDU to reach the power supply. Rated to operate up to 60 C (140 F) at full load ensures reliability and availability even in today's high-density deployments. One gigabit Ethernet/network port (10/100/1000) enhances and standardizes network connectivity. Two link ports are available to cascade to up to 32 PDUs, with a network port sharing (NPS) feature to enable power sharing between Rack PDUs in the cascading group. Track or bill power usage confidently with 1% metering accuracy. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs have the following certifications: UL, CE, CSA, UKCA, Nemiko, PSE, KC, China RoHS, RCM, and CMIM. This model’s input power cord is IEC-309 60 A 3P+N+PE and features 21 count C13/C15/C19/C21 combo outlets and 21 count C13/C15 outlets.